6903321d0eb33748005318.jpg
690336e43212b605056105.jpg
690344b46c209263263887.png
690368f545737565900985.png
6903321d0eb33748005318.jpg
690336e43212b605056105.jpg
690344b46c209263263887.png
690368f545737565900985.png

MFA0208 - Blower | 70 hPa | O2 compatible

This micro turbine features a patented motor cooling system fully isolated from the patient airflow, ensuring safe, stable, and long-term operation in medical environments. 

With dynamic performance up to 150 BPM, it is specifically designed for neonatal respiratory applications requiring rapid  response and extreme precision.

Document(s) to download

Specifications MFA0208 - Blower | 70 hPa | O2 compatible


APPLICATION
Hospital care, Emergency and Transport, Neonatal, Home care
RISE TIME*
< 86 ms
MAX STATIC PRESSURE (ΔP)
70 hPa
MAX FREE FLOW
> 340 l/mn
TYPE
Turbine without external casing
100% OXYGEN COMPATIBILITY
Yes
NOISE LEVEL*
< 61 dBa
TYP. POWER CONSUMPTION*
11.3 W
MOTOR COOLING MANAGEMENT
Yes - internal (independent from patient flow)
LIFETIME (L10)*
> 40 000 hours
PRESSURE RANGE (static)
< 90 hPa
VOLTAGE SUPPLY
24 VDC (nom) | 28 VDC (max)

Description MFA0208 - Blower | 70 hPa | O2 compatible


Its multipurpose design supports high pressure at low flow rates and can operate continuously with oxygen, making it ideal for advanced ventilation and gas delivery 

systems. 

The turbine also enables direct air-oxygen blending, producing a fully homogeneous gas mixture for optimal patient support.

Engineered for reliability, it safely operates at very low flow rates and offers an exceptional service life of over 40,000 hours under standard operating conditions.

   Key Performance Benefits

  • Pressure range up to 64 hPa at 80 l/mn
  • Blending air-oxygen through the turbine producing a full homogeneous gas
  • Capability to operate safely with very low flow rate (< 2l/mn)
  • Acceleration allowing to follow the breathing cycle of the patient up to 150 bpm
  • Naked turbine designed for integration by the manufacturer
  • Specific compressor architecture with a patented motor cooling system fully independent from the patient air flow - 100% O2 safe

Reliability of the system with patient support 24/7 and 365 days

Technical Highlights


Acceleration (rise time): < 86 ms @ 10A max -  from 5 to 60 hPa @30 l/mn


Noise level: < 61 dBa @ 30 hPa - @ 1m from air inlet


Power consumption: 11.3W @30 hPa @30 l/mn


LifeTime: > 40 000 hours - at standard operating conditions


Wire Length

Wire Length

150mm as standard or customised to requirements
Inlet tube

Inlet tube

With or without inlet tube