MFA0205 - Blower/microturbine | 78 hPa

It features a patented motor cooling system and is suitable for a wide range of standard respiratory applications such as Bi-level ventilation and home care devices.

A multipurpose model offering performance for pressure, flow and acceleration, with a long lifetime thanks to its patented cooling technology

Document(s) to download

Specifications MFA0205 - Blower/microturbine | 78 hPa


APPLICATION
Hospital care, Emergency and Transport, Neonatal, Home care
100% OXYGEN COMPATIBILITY
No
MAX STATIC PRESSURE (ΔP)
78 hPa
MAX FREE FLOW
280 l/mn
RISE TIME*
< 84 ms
NOISE LEVEL*
< 61 dBa
TYP. POWER CONSUMPTION*
11.0 W
MOTOR COOLING MANAGEMENT
Yes - internal
LIFETIME (L10)*
> 40 000 hours
TYPE
Turbine without external casing
VOLTAGE SUPPLY
24 VDC (nom) | 28 VDC (max)
PRESSURE RANGE (static)
< 90 hPa

Description MFA0205 - Blower/microturbine | 78 hPa


The MFA0205 is the ideal solution for manufacturers developing compact and efficient respiratory devices requiring high responsiveness, durability, and seamless integration.

This versatile model delivers an excellent balance of pressure, flow, and dynamic response, while ensuring a long operational lifetime thanks to its advanced cooling technology.

   Key Performance Benefits

  • Pressure output up to 68 hPa at 80 l/mn
  • Not compatible with Oxygen
  • Dynamic response capable of following patient breathing up to 120 bpm
  • Naked turbine design, optimized for OEM integration
  • Dedicated compressor architecture with patented motor cooling system to extend lifetime
  • Designed for reliable operation with patient support 24/7, 365 days a year

Technical Highlights


Acceleration (rise time): < 84 ms @ 10A max - from 5 to 60 hPa @30 l/mn


Noise level: < 61 dBa @ 30 hPa - @ 1m from air inlet


Power consumption: 11.0 W @ 30 hPa @ 30 l/mn


LifeTime: > 40 000 hours - at standard operating condition


Inlet tube

Inlet tube

With or without inlet tube
External suspension anti-vibration

External suspension anti-vibration

External suspension anti-vibration
Wire Length

Wire Length

150mm as standard or customised to requirements