MFA0500 - BlueBox Blower | 110 hPa | O2 compatible

The MFA0500 BlueBox is a high-pressure microturbine developed for manufacturers designing next-generation medical ventilators requiring compact architecture, precise airflow control and long-term reliability.

Delivering up to 110 hPa pressure and 380 L/min airflow, the turbine supports demanding ventilation modes while maintaining low acoustic emission and optimized energy efficiency. Its patented architecture separates motor cooling airflow from the patient circuit, ensuring thermal stability and safe continuous operation in clinical environments.


Specifications MFA0500 - BlueBox Blower | 110 hPa | O2 compatible


APPLICATION
Hospital care, Emergency and Transport, Neonatal, Home care
MAX STATIC PRESSURE (ΔP)
110 hPa
MAX FREE FLOW
380 l/mn
100% OXYGEN COMPATIBILITY
Yes
RISE TIME*
< 68 ms
NOISE LEVEL*
< 44 dBa
TYP. POWER CONSUMPTION*
12.5 W
MOTOR COOLING MANAGEMENT
Yes - internal (independent from patient flow)
NOISE LEVEL*
< 40 dBa
TYPE
BlueBox soundproofed casing
VOLTAGE SUPPLY
24 VDC (nom) | 25 VDC (max)
PRESSURE RANGE (static)
> 90 hPa

Description MFA0500 - BlueBox Blower | 110 hPa | O2 compatible


The MFA0500 enables direct air-oxygen mixing inside the turbine, fully compatible with 100% O₂, simplifying ventilator design and reducing system complexity.

Fast dynamic response (<68 ms) allows accurate tracking of breathing cycles, including neonatal and high-frequency applications.

Integrated within the BlueBox acoustic housing, the system reduces vibration and noise while accelerating OEM integration and shortening development time.

Designed for ventilator manufacturers developing ICU, portable, emergency or neonatal ventilation systems.

Key Performance Benefits

  • Pressure range up to 108 hPa at 80 l/mn
  • Blending air-oxygen through the turbine producing a full homogeneous gas, 100% O2 safe
  • Capability to operate safely with very low flow rate (< 2l/mn)
  • Acceleration allowing to follow the breathing cycle of the patient up to 200 bpm
  • Product fully soundproofed
  • Specific compressor architecture with a patented motor cooling system fully independent from the patient air flow - 100% O2 safe
  • Reliability of the system with patient support 24/7 and 365 days

Technical Highlights


Dynamic (rise time): < 68 ms @ 10A max - step from 5 to 60 hPa @30 l/mn


Noise level: < 40 dBa @50 hPa - @1m from air inlet


Power consumption: 12.5W @30 hPa @30 l/mn


LifeTime:  > 40 000 hours - at standard operating conditions


Air Filter

Air Filter

An air filter for the motor cooling inlet
Silicone ring for air inlet

Silicone ring for air inlet

Silicone sealant ring for the air inlet for increased sealing
Custom label

Custom label

Customised label with customised reference
Wire Length

Wire Length

150mm as standard or customised to requirements
Outlet port: male or female

Outlet port: male or female

Outlet port: male or female - ISO 5356-1