MFA0300 - BlueBox Blower | 90 hPa

The MFA0300 BlueBox Blower features a patented AIRFAN architecture with an integrated motor-cooling system, housed in a specially designed soundproof casing.

This advanced design ensures high performance, long service life, and extremely quiet operation.

Document(s) to download

Specifications MFA0300 - BlueBox Blower | 90 hPa


APPLICATION
Hospital care, Emergency and Transport, Neonatal, Home care
100% OXYGEN COMPATIBILITY
No
MAX STATIC PRESSURE (ΔP)
90 hPa
MAX FREE FLOW
320 l/mn
RISE TIME*
< 68 ms
NOISE LEVEL*
< 40 dBa
TYP. POWER CONSUMPTION*
12.5 W
MOTOR COOLING MANAGEMENT
Yes - internal (independent from patient flow)
LIFETIME (L10)*
> 40 000 hours
TYPE
BlueBox soundproofed casing
VOLTAGE SUPPLY
24 VDC (nom) | 28 VDC (max)
PRESSURE RANGE (static)
> 90 hPa

Description MFA0300 - BlueBox Blower | 90 hPa


The MFA0300 BlueBox is optimised for life-support applications—including acute care, sub-acute care, and homecare—the BlueBox blower delivers reliable airflow with exceptional acoustic comfort.

It is the only BlueBox turbine equipped with a dedicated oxygen outlet port, making it particularly suited for respiratory and ventilatory systems.

Customisation options include a silicone inlet sealing ring, customised labelling, variable wire lengths, male or female outlet ports and a specific port for O2.

   Key Performance Benefits

  • Pressure range up to 84 hPa at 80 l/mn
  • Safe operation at very low flow rate (< 2l/mn)
  • Rapid response to patient breathing cycles, up to 200 bpm
  • Fully soundproofed for low acoustic impact
  • Patented motor-cooling compressor architecture for extended lifetime
  • Designed for 24/7, 365-day reliability in patient support systems

Technical Highlights


Acceleration (rise time): 68ms @10A max - from 5 to 60 hPa @30 l/mn


Noise level: < 40 dBa @50 hPa - @1m from air inlet


Power consumption: 12.5 W @30 hPa @30 l/mn


LifeTime:  > 40 000 hours at standard operating condition


Silicone ring for air inlet

Silicone ring for air inlet

Silicone sealant ring for the air inlet for increased sealing
Custom label

Custom label

Customised label with customised reference
Wire Length

Wire Length

150mm as standard or customised to requirements
Special O2 outlet port

Special O2 outlet port

Special O2 outlet port
Outlet port: male or female

Outlet port: male or female

Outlet port: male or female - ISO 5356-1