651700043a672518156300.jpg
6517007b60e78104351216.jpg
6900b5baa5b01199961743.png
651700043a672518156300.jpg
6517007b60e78104351216.jpg
6900b5baa5b01199961743.png

MFA0295 - BlueBox Blower | 77 hPa | O2 compatible

The MFA0295 BlueBox Blower is built around patented AIRFAN technology, integrated within a protective, soundproofed BlueBox casing that enables oxygen management before the turbine.

This architecture ensures safe and homogeneous air–oxygen mixing while maintaining stable performance across a wide operating range.

Document(s) to download

Specifications MFA0295 - BlueBox Blower | 77 hPa | O2 compatible


APPLICATION
Hospital care, Emergency and Transport, Neonatal, Home care
100% OXYGEN COMPATIBILITY
Yes
MAX STATIC PRESSURE (ΔP)
77 hPa
MAX FREE FLOW
290 l/mn
RISE TIME*
< 84 ms
NOISE LEVEL*
< 41 dBa
TYP. POWER CONSUMPTION*
10.5 W
MOTOR COOLING MANAGEMENT
Yes - external
LIFETIME (L10)*
> 25 000 hours
TYPE
BlueBox soundproofed casing
VOLTAGE SUPPLY
24 VDC (nom) | 28 VDC (max)
PRESSURE RANGE (static)
< 90 hPa

Description MFA0295 - BlueBox Blower | 77 hPa | O2 compatible


Designed for both life-support and homecare applications, the MFA0295 offers an optimal balance of performance, efficiency, and acoustic comfort. Its economical design makes it well suited for long-term use, while its rapid dynamic response allows accurate tracking of patient breathing cycles, even at very low flow rates.

Fully compatible with oxygen and engineered for continuous operation, the MFA0295 provides dependable airflow delivery for respiratory devices requiring consistent performance, low noise, and long service life.

   Key Performance Benefits

  • Pressure range up to 70 hPa at 80 l/mn
  • Air–oxygen blending through the turbine for a homogeneous gas mixture
  • Fully O2 compatible
  • Safe operation at very low flow rate (< 2l/mn)
  • High dynamic response, following patient breathing up to 200 bpm
  • Product fully soundproofed for improved patient comfort
  • Designed for continuous operation with reliable 24/7 patient support

Technical Highlights


Acceleration (rise time): < 84 ms @ 10A max -  from 5 to 60 hPa @30 l/mn


Noise level: < 41 dBa @ 50 hPa - @ 1m from air inlet


Power consumption: 10.5 W @ 30 hPa @ 30 l/mn


Lifetime: > 25 000 hours - at standard operating conditions

Custom label

Custom label

Customised label with customised reference
Silicone ring for air inlet

Silicone ring for air inlet

Silicone sealant ring for the air inlet for increased sealing
Wire Length

Wire Length

150mm as standard or customised to requirements
Outlet port: male or female

Outlet port: male or female

Outlet port: male or female - ISO 5356-1