APPLICATION
Hospital care, Emergency and Transport
RISE TIME*
< 86 ms
MAX STATIC PRESSURE (ΔP)
> 130 hPa
MAX FREE FLOW
> 340 l/mn
TYPE
Anti-vibration casing (blower with dampers)
100% OXYGEN COMPATIBILITY
Yes
NOISE LEVEL*
< 52 dBa
TYP. POWER CONSUMPTION*
11.6 W
MOTOR COOLING MANAGEMENT
Yes - internal (independent from patient flow)
LIFETIME (L10)*
> 40 000 hours
PRESSURE RANGE (static)
> 90 hPa
VOLTAGE SUPPLY
24 VDC (nom) | 24 VDC (max)

Description MFA0249 - Blower w/ Dampers | 130 hPa | O2 compatible


Engineered for demanding applications, it delivers an excellent high-pressure performance ratio while enabling fast and easy integration thanks to its compact, anti-vibration housing.

Its advanced compressor architecture separates motor cooling from the patient airflow, ensuring safe operation with 100% oxygen.

Designed for continuous use, this blower offers reliable performance for life-saving patient assistance, 24 hours a day, 365 days a year.

   Key Performance Benefits

  • Pressure range up to 124 hPa at 80 l/mn
  • Blending air-oxygen through the turbine producing a full homogeneous gas
  • Compact design with integrated anti-vibration casing and dampers
  • Specific compressor architecture with a patented motor cooling system fully independent from the patient air flow - 100% O2 safe
  • Reliability of the system with patient support 24/7 and 365 days

Technical Highlights


Dynamic (rise time):   86 ms @ 10A max -  from 5 to 60 hPa @30 l/mn


Noise level:   < 52 dBa @30 hPa - @1m from air inlet


Power consumption:   11.6 W - @30 hPa @30 l/mn


LifeTime:   > 40 000 hours - at standard operating conditions


Custom label

Custom label

Customised label with customised reference
Wire Length

Wire Length

150mm as standard or customised to requirements
Outlet port: male or female

Outlet port: male or female

Outlet port: male or female - ISO 5356-1